New SAL-F Calibration Standards for Water Activity Meters
Allow fast and reliable calibration
Like every quality assurance lab instrument, water activity meters should be calibrated and verified frequently. Either saturated or unsaturated salt solutions can be used to perform this task on a water activity meter.
Novasina is the only supplier offering both options as the user should decide, which application form fits best for his calibration or verification requirements
SAL-F
New unsaturated Salt-Standards
To address the need for performing and completing fast and accurate verification or calibration tasks,
new SAL-F unsaturated salt standards have been developed.
Water activity meter calibration and verification
Novasina is the only manufacturer who offers both, saturated (SAL-T) and unsaturated (SAL-F) salt Standards. Depending on the application, it makes sense to use either SAL-F or SAL-T. Unsure which fits better? Please review the comparison below.
Saturated and unsaturated Salt-Standards
SAL-F (unsaturated)
The brand new SAL-F calibration salt standards were developed to meet customer demand for faster calibration capabilities. Especially at-line, time is a key and verification or calibration of a water activity meter should be done as fast as possible. Novasina has therefore maximized the speed of this task. The unsaturated salt solutions in combination with a aluminum insert and a fleece disk allows the fastest possible calibration or verification with a +/-0.003aw accuracy. Done by a real measurement means no predictor, no calculation of end value, no modelling. Fully compliant with ISO, AOAC, FDA and USP standards.
| Measurement speed | 5-7 min per point |
| Traceability | Greenspan / PTB |
| Certification | Not defined yet |
| Usability | One time |
| Accuracy | +/-0.003aw |
| Temperature range for cal/ver | 15-35°C |
| Shelf life | Max 2 years |
| Stability | Stable, but storage conditions need to be respected |
- Fast calibration and verification process
- Compliant with all international standards
- Unmatched accuracy and reliability in combination with a real measurement
- Accessories as aluminum cup and fleece disk to provide best possible prerequisite for fast emasurement
SAL-T (saturated)
The proven SAL-T calibration salt are well-known as the most accurate calibration and verification standards on this planet. These unmatched performance properties come with longer measurement times. Therefore, this standards are suitable where time is not critical like in quality control laboratories. A unbeatable advanatge of these saturated salt solutions: They are reusable and have a lifespan of 3-5 years.
| Measurement speed | 40-45 min per point |
| Traceability | Greenspan / PTB |
| Certification | UKAS |
| Usability | Multiple times |
| Accuracy | +/-0.003aw |
| Temperature range for cal/ver | 15-35°C |
| Shelf life | 3-5 years+ |
| Stability | very stable |
- Reusable
- Extended lifespan of 3-5 years
- Easy handling
- Compliant with all international standard
- Available as UKAS certified version
Novasina calibration salt standards
SAL-T salt standards
SAL-F salt standards
Find your contact person in your region
Our trained dealers can be found around the globe and will be happy to support you with your concerns.
Neuheimstrasse 12